VCP5000P-2G
The Industry originator of solder mask plugging.
Descriptions
Subvert the cumbersome process of traditional alignment, use the original positioning method, to achieve simple, stable mode of operation, in the vacuum state to complete the hole plugging operation, improve the quality of hole plugging.
Features
★Fast switchover between different types of PCBS in two minutes.
★No need for air guides when plugging holes, saving material consumption.
★Solutions for the operator which need the rich experience.
★The operating interface is automated, user-friendly and easy to operate.
★Solutions for the bubble problems in traditional plugging.
Specifications
Machine Size | 1841*844*2558㎜ |
Vacuum | -0.99bar/-99kpa (Plugging green oil can be satisfied with just -0.55bar) |
Panel thickness | 0.3-5.0mm |
Panel Size | 660*863mm |
Through-hole plugging | Hole diameter:0.1-0.5mm (the difference between large and small holes on the same plate should not be more than 0.15mm hole diameter after plating); AR value: ≦20:1 |
Top Copper Thick Plating | ≦5.0OZ(Difference in copper thickness of plate <30um) |
Plugging hole distance from board edge | Min. 14mm |
Plugging Methods | Plugging selection (top to bottom) |
Production noise | ≦75dB |
Plugging speed | 2-80mm/sec(adjustable) |
Plugging Hole Pressure | 0-6bar(adjustable) |
Paste Pressure | 0-6bar(adjustable) |
Paste Viscosity | 250-300dpa.s |
Plywood Base | Specific processing according to the positioning holes on the board edge of the printed circuit board, to meet the common use of all sizes of boards. |
Operation Panel | Touch-screen operation |
Protection Devices | Safety grids, emergency stops |
Paste Addition Method | Single ink clip replacement (500g of ink per clip) |
Failure Rate | ≦1/400h(Failure time/equipment uptime) |
Height of operating table | 1000±100mm |
Production Capacity
Capacity is affected by aspect ratio (Panel Thickness, Aperture Diameter), Paste Viscosity. | Capacity | Aspect ratio | No. of plugging hole cutters |
Capacity per hour | 20-70 | Max:20:1 | 1-2 |
Communal Requirement
Electrical requirements | |
Electric | Three-phase five-wire 380V,Energy consumption of equipment 8.8KW/H |
Pressure of compressed air | ≧6.5bar;耗气/air consumption:1m³/H |
Vacuum Pump Discharge Volume | 20m³/h (exhaust port:φ80mm) |
Compressed air volume | 0.08m³/h(exhaust port:φ10mm) |
Equipment installation environment (temperature, humidity and dust-free requirements) | A. Environmental requirements: clean room, 100,000 level↑. B. Temperature requirement: 22±2℃. C. Humidity requirements: 50±5%. |